中文 | ENG

第58卷 第2期 2025-3
Predatory publisher and low standard journal: An emerging problem in clinical surgery field

.........................

第58卷 第2期 2025-3
Conflict of interest in clinical surgery: Contemporary concern in digital era

.........................

第58卷 第2期 2025-3
Postpublication redecision and pitfalls of inadequate standards in scientific surgical journals: Important consideration in academic publication

.........................

第58卷 第2期 2025-3
Spontaneous bilateral basal ganglia hemorrhage

.........................

第58卷 第2期 2025-3
Academic characterization of the Formosan Journal of Surgery: A five-year bibliometric analysis

.........................

第58卷 第2期 2025-3
Supra-sternal reconstruction for a high-hanging fruit like right subclavian artery aneurysm

.........................

第58卷 第2期 2025-3
Operations for choledochal cysts: A 25-year experience at a tertiary care center in India

.........................

第58卷 第2期 2025-3
A case report: Can a titanised polypropylene mesh (TiMesh) obviate a dual mesh for sandwich technique for parastomal hernias?

.........................

第58卷 第2期 2025-3
Recurrent gallstone ileus, a deadly encounter: A case report

.........................

第58卷 第2期 2025-3
The changes in dietary intake and tolerance for Chinese food after bariatric surgery in Taiwan

.........................

第58卷 第2期 2025-3
Diagnostic value of trans-recto-perineal ultrasound in perianal fistula—preoperative versus intraoperative findings: A comparative cross-section study

.........................

第58卷 第2期 2025-3
Efficacy and safety of extended-release dinalbuphine sebacate for postoperative analgesia: A systematic review and meta-analysis

.........................

第58卷 第2期 2025-3
Dynamic changes in segmented neutrophil-to-monocyte ratio in trauma patients with stress-induced hyperglycemia: A retrospective study

.........................

第58卷 第1期 2025-1
Ensuring authorship qualification in clinical research articles: A focus on surgical therapy studies

.........................

第58卷 第1期 2025-1
Estimated risk for transfusion of monkeypox contaminated perioperative blood transfusion: A call to action for stronger regulations and testing protocols

.........................

第58卷 第1期 2025-1
Insights into traumatic and crisis surgery: Implications of data analysis in conflict zones

.........................

第58卷 第1期 2025-1
Tongue peeling as an adverse reaction with use of micronized purified flavonoid: A case report

.........................

第58卷 第1期 2025-1
Pilonidal sinus of scrotum: A rare clinical entity

.........................

第58卷 第1期 2025-1
Incidental autopsy finding of retiform hemangioendothelioma of the spleen

.........................

第58卷 第1期 2025-1
Retroperitoneal laparoscopy for hydronephrosis due to multiple fibroepithelial polyps: A case series

.........................
登入帳號才能閱讀全文
 
篇名 Kyphoplasty with an intravertebral reduction device for osteoporotic vertebral compression fractures with spinal canal encroachment
作者 Jia‑En Chi, Jia‑Yuan Hsu, Ryan Wing Yuk Chan, Wen‑Cheng Lo, Yung‑Hsiao Chiang, Jiann‑Her Lin
卷期/出版年月 53卷1期 (2020/2)
頁次 20-28
摘要 Background: To compare the radiological and clinical outcomes of kyphoplasty (KP) with intravertebral reduction device (IRD) and vertebroplasty (VP) for treating osteoporotic vertebral compression fracture (OVCF)‑associated spinal canal encroachment (SCE). Materials and Methods: From January 2013 to December 2016, 57 patients with OVCF‑associated SCE treated through VP or KP with an IRD were enrolled. Kyphotic angle (KA) anterior, middle, and posterior body heights (ABH, MBH, and PBH, respectively) at postoperative week 1 3, 6, and 12 months of the cemented vertebrae were evaluated. Visual analog scale (VAS), Oswestry Disability Index (ODI), and EuroQol‑5D‑5 L (EQ‑5D‑5 L) were followed, and the complications were recorded. Results: Sixteen and 41 patients were treated through KP with IRD and VP (IRD and VP groups, respectively), and their characteristics were comparable. Compared with the VP group, KA, ABH, MBH, and PBH in the IRD group were significantly greater after the operation at postoperative 12 months (IRD vs. VP: KA −1.68° ± 6.02° vs. −10.34° ± 4.99°; ABH 2.06 ± 0.29 vs. 1.35 ± 0.26; MBH 2.21 ± 0.51 vs. 1.21 ± 0.31; PBH 2.91 ± 0.62 vs. 2.11 ± 0.33 cm, P < 0.05). Significant postoperative improvements were observed in the VAS, ODI, and EQ‑5D‑5 L in both groups; these improvements were similar between the two groups. No new neurological deficits occurred, and the incidence rates of cement leakage into the SC were similar. Conclusions: KP with IRD was associated with better body heights and KA at least for 1 year for OVCF‑associated SCE with noninferior clinical outcomes to VP.
關鍵詞 Compression fracture, intravertebral reduction device, kyphoplasty, osteoporosis, refracture, spinal canal encroachment, vertebroplasty
分類 Original Article

台灣外科醫學會雜誌 © 2006 Taiwan Surgical Association All Rights Reserved
會 址:台北市南京東路五段 31 號 3 樓
電 話:(02) 2769-7845 傳 真:(02) 2746-7149 Email: journal@surgery.org.tw